- Disconnect the 4P connector (A) from the actuator (B).
Terminal side of male terminals
- Remove the cover (A), and check the output linkage (B) for smooth movement.
- Connect the battery power to the No. 2 terminal and ground to the No. 1 terminal.
- Check for a clicking sound from the magnetic clutch. The output linkage should be locked.
- If the output linkage is not locked, replace the actuator assembly.
| |
- Check the operation of the actuator motor in each output linkage position according to the table. You should be able to hear the motor.
Battery power polarities |
Output linkage position |
(+) |
(-) |
FULL CLOSE |
MIDDLE POSITION |
FULL OPEN |
No. 4 Terminal |
No. 3 Terminal |
The motor runs. |
The motor runs. |
The motor stops. |
No. 3 Terminal |
No. 4 Terminal |
The motor stops. |
The motor runs. |
The motor runs. |
- FULL OPEN
- OUTPUT LINKAGE
- FULL CLOSE
- MIDDLE POSITION
|