Keyless/Power Door Lock System
|
22-235 |
Cavity | Wire | Test condition | Test: Desired result | Possible cause if result is not obtained | ||
3 | BLK | Under all conditions | Check for continuity to ground:
There should be continuity. |
|
||
2 | YEL/BLK | Connect the No. 2 terminal to the No. 7 terminal and the No. 6 terminal to the No. 3 terminal momentarily with ignition switch ON (II) | Check actuator operation:
The actuator should lock. |
|
||
7 | LT GRN [GRY] | |||||
5 | YEL | Connect the No. 5 terminal to the No. 6 terminal and the No. 7 terminal to the No. 3 terminal momentarily with ignition switch ON (II) | Check actuator operation:
The actuator should unlock. |
|||
6 | LT GRN/RED [GRY/BLU] | |||||
4 | LT GRN/BLK [GRY/RED] | Under all condition | Check for continuity between the No. 4 terminal and No. 7 terminal of the actuator.
There should be continuity. |
|
[ ]: Passenger's