Open the trunk lid. 
	Carefully pry out the trunk light (A).
  
 
	Disconnect the 2P connector (B) from the light.Check for continuity between the No. 1 (+) and No. 2 (–) terminals. There should be continuity.
If there is no continuity, check the bulb. If the bulb is OK, replace the trunk light.
 |  | 
Open the trunk lid. 
	Disconnect the 2P connector (A) from the trunk lid latch (B).  
 
	Check for continuity between the No. 1 and No. 2 terminals. 
	There should be continuity with the trunk lid open.There should be no continuity with the trunk lid closed. |