Heating
 | 
21-29 | 
 
 HEATER CONTROL PANEL CONNECTOR A (14P) 
 Wire side of terminal terminals Is there continuity? YES - Repair any short to body ground in the wire(s) between the heater control panel and the power transistor.  NO - Go to step 14. 
 HEATER CONTROL PANEL CONNECTOR A (14P) 
 Wire side of female terminals Is there continuity? YES - Go to step 15. NO - Repair any open in the wire(s) between the heater control panel and the power transistor.   | 
 
 Is the power transistor OK? YES - Check for loose wires or poor connections at heater control panel connector A (14P) and at the power transistor 4P connector. If the connections are good, substitute a known-good heater control panel and recheck. If the symptom/indication goes away, replace the original heater control panel.  NO - Replace the power transistor.  
 BLOWER MOTOR 2P CONNECTOR 
 Wire side of female terminals Is there battery voltage? YES - Replace the blower motor.  NO - Go to step 20. 
 Is the relay OK? YES - Go to step 22. NO - Replace the blower motor relay.   |