Heating
 | 
21-28 | 
| 
5-door KE Model
 DTC 12: A Problem in the Blower Motor Circuit 
 Are the fuses OK? YES - Go to step 2. NO - Replace the fuse(s) and recheck.  
 BLOWER MOTOR 2P CONNECTOR 
 Wire side of female terminal 
 Does the blower motor run? YES - Go to step 4. NO - Go to step 17. 
  | 
 POWER TRANSISTOR 4P CONNECTOR 
 Wire side female terminals Is there continuity? YES - Go to step 8. NO - Check for an open in the wire between the power transistor and body ground. If the wire is OK, check for poor ground at G501.  
 POWER TRANSISTOR 4P CONNECTOR 
 Wire side of female terminals 
 Does the blower motor run at high speed? YES - Go to step 10. NO - Repair open in the wire between the power transistor and the blower motor.  
  |