RADIATOR FAN RELAY 4P SOCKET RADIATOR FAN MOTOR 2P CONNECTOR Is there continuity? YES - Go to step 8. NO - Repair open in the wire between the under-hood fuse/relay box and the radiator fan motor 2P connector terminal No. 2.
RADIATOR FAN MOTOR 2P CONNECTOR Wire side of female terminals Is there continuity? YES - Replace the radiator fan motor. NO - Check for an open in the wire between radiator fan motor 2P connector terminal No. 1 and body ground. If the wire is OK, check for a poor ground at G301. |
RADIATOR FAN SWITCH 2P CONNECTOR Wire side of female terminals Does the radiator fan run? YES - Replace the radiator fan switch. NO - Go to step 12.
RADIATOR FAN SWITCH 2P CONNECTOR Is there battery voltage? YES - Check for an open in the wire between radiator fan switch 2P connector terminal No. 1 and body ground. If the wire is OK, check for a poor ground at G301. NO - Repair open in the wire between the radiator fan switch terminal No. 2 and the under-hood fuse/relay box. |