23-128 |
U2o CONNECTOR Wire side of female terminals Is the resistance as specified? YES - Faulty right side impact sensor or SRS unit; replace the right side impact sensor. If the problem is still present, replace the SRS unit. NO - Open in the floor wire harness; replace the floor wire harness. |
DTC 14-4: Faulty Power Supply to the Right Side Impact Sensor (Without OPDS Unit Model)
Does the SRS indicator light stay on? YES - Go to step 3. NO - Intermittent failure, system is OK at this time. Go to Troubleshooting Intermittent Failures (see page 23-38).
|