- Remove the bolt, the ground terminal (A) and the holder (B). Disconnect the field coil connector (C), then remove the thermal protector (D).
- Replace the thermal protector (A) with a new one and apply silicone sealant (B) to the bottom of the thermal protector.
- Install in the reverse order of removal.
| |
- Discharge the refrigerant (see page 21-94).
- Remove the cover (A), the relief valve (B) and the O-ring (C). Plug the opening to keep foreign matter from entering the system and the compressor oil from running out.
- Clean the mating surfaces.
- Replace the O-ring with a new one at the relief valve and apply a thin coat of refrigerant oil before installing it.
- Remove the plug and install and tighten the relief valve.
- Charge the system (see page 21-96) and check for system performance (see page 21-98).
|