Except 4-door, 5-door KE Model
- DIALS
- HEATER FAN SWITCH
- BULBS
- AIR MIX CONTROL CABLE
- MODE CONTROL CABLE

Air Mix and Mode Control Cables Replacement
- When installing the air mix control cable, set the temperature control dial to MAX COOL. When installing the mode control cable, set the mode control dial to VENT.
- Attach the control cable (A) to the control lever (B) as shown.
- Adjust the length between the inner cable (A) and the cable housing (B) of the heater unit side to 28 ±; 0.3 mm as shown.
- Keep the length of the control cable adjusted in step 3, hold the control cable with the cable clamp.
|  |
Except 4-door, 5-door KE Model
Check for continuity between the terminals in each switch position according to the table.


|