5-door Except KE Model
- Turn the ignition switch ON (II) and the heater fan switch ON.
Does the blower run?
YES - Go to step 2.
NO - Go to step 16.
- Turn the heater fan switch OFF.
- Make sure the ignition switch is ON (II).
Does the blower motor run?
YES - Go to step 4.
NO -Go to step 9.
- Turn the ignition switch OFF.
- Disconnect the blower motor 2P connector.
- Disconnect the blower resistor 5P connector.
- Disconnect the heater fan switch 7P connector.
- Check for continuity between the No. 1, 5, 6 and 7 terminals of the heater fan switch 7P connector and body ground individually.
HEATER FAN SWITCH 7P CONNECTOR
Wire side of female terminals
Is there continuity?
YES - Repair any short to body ground in the wire(s) between the blower motor, the blower resistor and the heater fan switch.
NO - Replace the heater fan switch.
| |
- Turn the ignition switch OFF.
- Disconnect the blower resistor 5P connector.
- Measure the resistance between the No. 1 and No. 5 terminals of the blower resistor.
BLOWER RESISTOR
Is there about 2 - 3 ohm?
YES - Go to step 12.
NO - Replace the blower resistor.
- Reconnect the blower resistor 5P connector.
- Disconnect the heater fan switch 7P connector.
- Turn the ignition switch ON (II).
|