Heating
|
21-17 |
4-door
DTC 10: An Open or Short in the Mode Control Motor Circuit
HEATER CONTROL PANEL CONNECTOR A (14P) Wire side of female terminals HEATER CONTROL PANEL CONNECTOR B (22P) Wire side of female terminals Is there continuity? YES - Repair any short to body ground in the wire(s) between the heater control panel and the mode control motor. NO - Go to step 4. |
HEATER CONTROL PANEL CONNECTOR A (14P) Wire side of female terminals HEATER CONTROL PANEL CONNECTOR B (22P) Wire side of female terminals Is there any voltage? YES - Repair any short to power in the wire(s) between the heater control panel and the mode control motor. This short also damages the heater control panel. Repair the short to power before replacing the heater control panel. NO - Go to step 5. |