Climate ControlRecirculation Control Motor Circuit Troubleshooting (cont'd) |
21-145 | ECT Sensor Circuit Troubleshooting |
CLIMATE CONTROL UNIT CONNECTOR A (14P) Wire side of female terminals RECIRCULATION CONTROL MOTOR 5P CONNECTOR Wire side of female terminals Is there continuity? YES - Check for loose wires or poor connections at climate control unit connector A (14P) and at recirculation control motor 7P connector. If the connections are good, substitute a known-good climate control unit and recheck. If the symptom/indication goes away, replace the original climate control unit. NO - Repair any open in the wire(s) between the climate control unit and the recirculation control motor.
Do the recirculation control linkage and doors move smoothly? YES - Replace the recirculation control motor. NO - Repair the recirculation control linkage or doors. | ![]() |
Does the malfunction indicator lamp come on? YES - Refer to the fuel and emissions section (see page 11-3). NO - Go to step 2.
CLIMATE CONTROL UNIT CONNECTOR B (22P) Wire side of female terminals Is there about 5 V? YES - Check for loose wires or poor connections at climate control unit connector B (22P) and at the ECT sensor 2P connector. If the connections are good, substitute a known-good climate control unit and recheck. If the symptom/indication goes away, replace the original climate control unit. NO - Repair open in the wire between the climate control unit and the ECT sensor. |