DTC 14: An Open in the Evaporator Temperature Sensor Circuit
EVAPORATOR TEMPERATURE SENSOR
Terminal side of male terminals
Is the resistance within the specifications shown on the graph? YES - Go to step 3. NO - Replace the evaporator temperature sensor.
|
CLIMATE CONTROL UNIT CONNECTOR B (22P) Wire side of female terminals
EVAPORATOR TEMPERATURE SENSOR 2P CONNECTOR Wire side of female terminals Is there continuity? YES - Go to step 5. NO - Repair open in the wire between the climate control unit and the evaporator temperature sensor.
|