Climate Control
|
21-135 |
5-door
DTC 10: An Open or Short in the Mode Control Motor Circuit
CLIMATE CONTROL UNIT CONNECTOR A (14P) Wire side of female terminals CLIMATE CONTROL UNIT CONNECTOR B (22P) Wire side of female terminals Is there continuity? YES - Repair any short to body ground in the wire(s) between the climate control unit and the mode control motor. NO - Go to step 4. |
CLIMATE CONTROL UNIT CONNECTOR A (14P) Wire side of female terminals CLIMATE CONTROL UNIT CONNECTOR B (22P) Wire side of female terminals Is there any voltage? YES - Repair any short to power in the wire(s) between the climate control unit and the mode control motor. This short also damages the climate control unit. Repair the short to power before replacing the climate control unit. NO - Go to step 5. |