CLIMATE CONTROL UNIT CONNECTOR A (14P) Wire side of female terminals SUNLIGHT SENSOR 2P CONNECTOR Wire side of female terminals Is there continuity? YES - Go to step 5. NO - Repair open in the wire between the climate control unit and the sunlight sensor.
Is the sunlight sensor OK? YES - Check for loose wires or poor connections at climate control unit connectors A (14P) and B (22P) and at the sunlight sensor 2P connector. If the connections are good, substitute a known-good climate control unit and recheck. If the symptom/indication goes away, replace the original climate control unit. NO - Replace the sunlight sensor. |
5-door
DTC 6: A Short in the Sunlight Sensor Circuit
CLIMATE CONTROL UNIT CONNECTOR B (22P) Wire side of female terminals Is there continuity? YES - Repair short to body ground in the wire between the climate control unit and the sunlight sensor. NO - Go to step 4.
Is the sunlight sensor OK? YES - Substitute a known-good climate control unit and recheck. If the symptom/indication goes away, replace the original climate control unit. NO - Replace the sunlight sensor. |