Climate Control
|
21-124 |
CLIMATE CONTROL UNIT CONNECTION A (14P) Wire side of female terminals Is there continuity? YES - Repair any short to body ground in the wire(s) between the climate control unit and the power transistor. NO - Go to step 14.
CLIMATE CONTROL UNIT CONNECTOR A (14P) Wire side of female terminals POWER TRANSISTOR 4P CONNECTOR Wire side of female terminals Is there continuity? YES - Go to step 15. NO - Repair any open in the wire(s) between the climate control unit and the power transistor. |
Is the power transistor OK? YES - Check for loose wires or poor connections at climate control unit connector A (14P) and at the power transistor 4P connector. If the connections are good, substitute a known-good climate control unit and recheck. If the symptom/indication goes away, replace the original climate control unit. NO - Replace the power transistor.
BLOWER MOTOR 2P CONNECTOR Wire side of female terminals Is there battery voltage? YES - Replace the blower motor. NO - Go to step 20.
Is there relay OK? YES - Go to step 22. NO - Replace the blower motor relay. |