PGM-FI System

DTC Troubleshooting (cont'd)

11-66  

  1. At the wire harness side, check for continuity between TP sensor 3P connector terminal No. 2 and body ground.

TP SENSOR 3P CONNECTOR

Wire side of female terminals

Is there continuity?

YES

- Repair short in the wire between the ECM/PCM (A15) and the TP sensor.

NO

- Go to step 12.


  1. Connect ECM/PCM connector terminal A15 and body ground with a jumper wire.

ECM/PCM CONNECTOR A (31P)

Wire side of female terminals

  1. At the wire harness side, check for continuity between TP sensor 3P connector terminals No. 2 and body ground.

TP SENSOR 3P CONNECTOR

Wire side of female terminals

Is there continuity?

YES

- Substitute a known-good ECM/PCM and recheck (see page 11-6). If symptom/indication goes away, replace the original ECM/PCM.

NO

- Repair open in the wire between the ECM/PCM (A15) and the TP sensor.


  1. Measure voltage between ECM/PCM connector terminals A10 and A20.

ECM/PCM CONNECTOR A (31P)

Wire side of female terminals

Is there about 5 V?

YES

- Repair open in the wire between the ECM/PCM (A20) and the TP sensor.

NO

- Substitute a known-good ECM/PCM and recheck (see page 11-6). If symptom/indication goes away, replace the original ECM/PCM.