- Connect the IAC valve 3P connector terminal No. 3 and body ground with a jumper wire.
IAC VALVE 3P CONNECTOR
Wire side of female terminals
- Check for continuity between ECM/PCM connector terminal A12 and body ground.
ECM/PCM CONNECTOR A (31P)
Wire side of female terminals
Is there continuity?
YES |
- Go to step 13. |
NO |
- Repair open in the wire between the IAC valve and the ECM/PCM (A12). |
| |
- Remove the jumper wire from the IAC valve 3P connector, then reconnect the IAC valve 3P connector.
- Turn the ignition switch ON (II).
- Measure voltage between body ground and ECM/PCM connector terminal A12.
ECM/PCM CONNECTOR A (31P)
Wire side of female terminals
Is there battery voltage?
YES |
- Substitute a known-good ECM/PCM and recheck. If symptom/indication goes away, replace the original ECM/PCM. |
NO |
- Replace the IAC valve. |
|