Connect the PGM-FI main relay 2 4P connector terminals No. 1 and No. 2 with a jumper wire. Wire side of female terminals
 
	Turn the ignition switch ON (II).Measure voltage between the fuel pump 5P connector terminal No. 5 and body ground within the first 2 seconds after the ignition switch was turned ON (II). FUEL PUMP 5P CONNECTOR
 Wire side of female terminals
 Is there battery voltage? 
| YES | - Replace the PGM-FI main relay 2.   |  
| NO | - Repair open in the wire between the PGM-FI main relay 2 and the fuel pump 5P connector.   |  
 
	Turn the ignition switch OFF. |  | 
Check for continuity between the fuel pump 5P connector terminal No. 4 and body ground. FUEL PUMP 5P CONNECTOR
 Wire side of female terminals
 Is there continuity? 
| YES | - Replace the fuel pump.   |  
| NO | - Repair open in the wire between the fuel pump 5P connector and G551.   |  
 |