- At the wire harness side, check for continuity between TP sensor 3P connector terminal No. 2 and body ground.
TP SENSOR 3P CONNECTOR
Wire side of female terminals
Is there continuity?
YES |
- Repair short in the wire between the ECM/PCM (A15) and the TP sensor. |
NO |
- Go to step 12. |
- Connect ECM/PCM connector terminal A15 and body ground with a jumper wire.
ECM/PCM CONNECTOR A (31P)
Wire side of female terminals
| |
- At the wire harness side, check for continuity between TP sensor 3P connector terminals No. 2 and body ground.
TP SENSOR 3P CONNECTOR
Wire side of female terminals
Is there continuity?
YES |
- Substitute a known-good ECM/PCM and recheck (see page 11-313). If symptom/indication goes away, replace the original ECM/PCM. |
NO |
- Repair open in the wire between the ECM/PCM (A15) and the TP sensor. |
- Measure voltage between ECM/PCM connector terminals A10 and A20.
ECM/PCM CONNECTOR A (31P)
Wire side of female terminals
Is there about 5 V?
YES |
- Repair open in the wire between the ECM/PCM (A20) and the TP sensor. |
NO |
- Substitute a known-good ECM/PCM and recheck (see page 11-313). If symptom/indication goes away, replace the original ECM/PCM. |
|