PGM-FI System

DTC Troubleshooting (cont'd)

11-243  

  1. Disconnect ECM/PCM connector B (24P).
  1. Check for continuity between ECM/PCM connector terminal B15 and body ground.

ECM/PCM CONNECTOR B (24P)

Wire side of female terminals

Is there continuity?

YES

- Repair short in the wire between the VTEC solenoid valve and the ECM/PCM (B15).

NO

- Go to step 12.


  1. Connect the VTEC solenoid valve 1P (2P)* connector terminal No. 1 and body ground with a jumper wire.

VTEC SOLENOID VALVE HARNESS CONNECTORS

Wire side of female terminal

Wire side of female terminal
  1. Check for continuity between ECM/PCM connector terminal B15 and body ground.

ECM/PCM CONNECTOR B (24P)

Wire side of female terminals

Is there continuity?

YES

- Go to step 14.

NO

- Repair short in the wire between the VTEC solenoid valve and the ECM/PCM (B15).