- Turn the ignition switch OFF.
- Measure voltage between ECM/PCM connector terminal E7 and body ground.
ECM/PCM CONNECTOR E (31P)
Wire side of female terminals
Is there battery voltage?
YES |
- Go to step 45. |
NO |
- Go to step 42. |
- Remove the PGM-FI main relay 1 (A).
LHD model:
RHD model:
| |
- Measure voltage between the PGM-FI main relay 1 4P connector terminal No. 4 and body ground.
Wire side of female terminals
Is there battery voltage?
YES |
- Go to step 44. |
NO |
- Repair open in the wire between the No. 6 ECU (ECM/PCM) (15 A) fuse and the PGM-FI main relay 1. |
- Check for continuity between the PGM-FI main relay 1 4P connector terminal No. 3 and ECM/PCM connector terminal E7.
Wire side of female terminals
Is there continuity?
YES |
- Test the PGM-FI main relay 1 (see page 22-80). If the relay is OK, substitute a known-good ECM/PCM and recheck (see page 11-6). If symptom/indication goes away, replace the original ECM/PCM. |
NO |