| Fan Controls
 | 10-17 | 
| 
 
 RADIATOR FAN RELAY 4P SOCKET Terminal side of female terminals 
 Wire side of female terminals RADIATOR FAN MOTOR 2P CONNECTOR Is there continuity? YES - Go to step 8. NO - Repair open in the wire between the under-hood fuse/relay box and the radiator fan motor 2P connector terminal No. 2.  
 RADIATOR FAN MOTOR 2P CONNECTOR 
 Wire side of female terminals Is there continuity? YES - Replace the radiator fan motor.  NO - Check for an open in the wire between radiator fan motor 2P connector terminal No. 1 and body ground. If the wire is OK, check for a poor ground at G201.  |  | 
 
 Does the radiator fan run? YES - Replace the radiator fan switch.  NO - Go to step 11. 
 RADIATOR FAN SWITCH 2P CONNECTOR 
 Wire side of female terminals Is there battery voltage? YES - Check for an open in the wire between radiator fan switch 2P connector terminal No. 1 and body ground. If the wire is OK, check for a poor ground at G101.  NO - Repair open in the wire between the radiator fan switch terminal No. 2 and the under-hood fuse/relay box.  |