| Check the housing-to-outer rotor radial clearance between the outer rotor (A) and pump housing (B). If the housing-to-outer rotor radial clearance exceeds the service limit, replace the oil pump.
Housing-to-Outer Rotor Radial Clearance
 Standard (New): 0.15 - 0.21 mm  (0.006 - 0.008 in.) Service Limit: 0.23 mm (0.009 in.) 
 Inspect both rotors and the pump housing for scoring or other damage. Replace parts if necessary.
 Install the oil pump cover.
 | 
 | Oil Pump Installation Install the oil pump.
 
 Squeeze the new oil pump chain tensioner (A), then install the set clip (B) on it as shown.
NOTE: The set clip is supplied with the oil pump chain tensioner.
 
 |