PGM-FI System
 | 
11-76 | 
 ECM/PCM CONNECTOR E (31P) 
 Wire side of female terminals Is there battery voltage? YES - Go to step 13. NO - Substitute a known-good ECM/PCM and recheck.  If symptom/indication goes away, replace the original ECM/PCM.   
 ECM/PCM CONNECTOR A (31P) 
 Wire side of female terminals Is there battery voltage? YES - Go to step 15. NO - Substitute a known-good ECM/PCM and recheck.  If symptom/indication goes away, replace the original ECM/PCM.    | 
 
 
 ECM/PCM CONNECTOR A (31P) 
 Wire side of female terminals Is there battery voltage? YES - Repair short to power in the wire between the ECM/PCM (A2, A3) and the PGM-FI main relay 1.   NO - Replace the PGM-FI main relay 1.    |